Quick-Opening Electric Actuator
The quick-opening actuator is specifically designed for rapid opening and closing of valves, capable of completing the full stroke operation (0-90°) within 3 to 8 seconds. It is primarily used for emergency shut-off or fast response control applications, featuring both high reliability and long service life design.
Tags

As Featured In
Power Supply
AC 110V / 220V / 380V
DC 12V / 24V
High efficiency
low power consumption, high torque
Torque
20~2000NM
Ingress Protection
Dustproof and waterproof with an IP67 rating
Accuracy
Hysteresis<0.5%
Dead Zone<0.5%
Feedback Error<0.5%
Valve Adaptable
0~90°
ball valve
butterfly valve
I/O
4-20mA
0-10V
Modbus
Optional Function
Dehumidification and heating
Passive contact switch
Over-torque protection

Model Representation Method

| Quick-Opening Electric Actuator | ||||||||
|---|---|---|---|---|---|---|---|---|
| Output Torque | 10N·m | 20N·m | 50N·m | 75N·m | 100N·m | 200N·m | 500N·m | |
| Recommended Valve Adaptation | Ball Valve | DN15 | DN20 | DN25-32 | DN40 | DN50-65 | DN80-100 | DN125-200 |
| Butterfly Valve | DN40 | DN50-65 | DN80-100 | DN125 | DN150 | DN200 | DN250-300 | |
| Action Time | 3S/4S/6S | 3S/4S/6S | 4S/6S | 6S/8S | 6S/8S | 6S/8S | 8S | |
| Rotation Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° | |
| Motor Power | AC220V | 10W | 25W | 40W | 90W | 90W | 120W | 140W |
| AC380V | 6W | 15W | 30W | 40W | 40W | 90W | 120W | |
| DC24V | 13W | 25W | 35W | 70W | 70W | 0 | 0 | |
| Rated Current | AC220V | 0.16A | 0.32A | 0.35A | 0.54A | 0.64A | 0.96A | 1.03A |
| AC380V | 0.07A | 0.10A | 0.15A | 0.29A | 0.29A | 0.45A | 0 | |
| DC24V | 1.28A | 2.03A | 3.57A | 5.13A | 3.04A | 0 | 0 | |
| Weight | 2.5kg | 3.5kg | 8kg | 8.5kg | 9kg | 20kg | 22kg | |
| Power Supply | AC 110V, AC 220V, AC 380V, DC 24V, DC 220V (selectable) | |||||||
| Accuracy | Backlash≤0.5% Dead Zone≤0.5% Feedback Error≤0.5% | |||||||
| Insulation Resistance | 100 MΩ at 500 V DC | |||||||
| Withstand Voltage | 1,500 V AC for 1 minute | |||||||
| Protection Rating | IP67 | |||||||
| Limit Components | ■ Electric operation: Full open/close limit switches ■ Manual operation: Mechanical stops |
|||||||
| Protection Device | Overheat protector (auto-resetting type) | |||||||
| Installation Orientation | 360° adjustable | |||||||
| Electrical Interface | M20×1.5 waterproof cable glands×2 (1 for power cable, 1 for signal cable) | |||||||
| Ambient Temperature | Standard: -30℃ to 60℃ ▲High-temperature type: -50℃ to 125℃ |
|||||||
| Testing Standard | JB/T8219-2016 | |||||||
Dimension drawing
10N·m

20N·m

50N·m

200N·m

500N·m

Circuit Diagram

S

MS

PIU

CPT

PCU

G

SP