Application of Mini Electric Valves in Data Center Liquid Cooling Systems

As data centers accelerate upgrades toward high density and high computing power, liquid cooling technology has become the mainstream heat dissipation solution to solve the heat management bottleneck. Among them, mini electric butterfly valves are critical supporting components that determine the stable and efficient operation of liquid cooling systems. Rooted in the actual needs of the data center industry, GRAT Control has launched dedicated mini electric control valves for data centers, adopting scenario-specific optimized design to effectively solve the core control pain points of liquid cooling systems and empower the green and stable operation of data centers.

I. Core Adaptation Requirements for Valves in Data Center Liquid Cooling

The reliability, temperature control accuracy and energy efficiency of data center liquid cooling systems depend heavily on high-performance pipeline control components. Considering that data centers need to operate 7×24 hours uninterrupted, liquid cooling system valves must meet the following key adaptation requirements to ensure long-term stable operation:

Application of Micro Electric Valves in Data Center Liquid Cooling Systems 2

1. High Sealing Performance (Core Safety Requirement)

It is necessary to completely eliminate the leakage of cold and hot water, ethylene glycol and other liquid cooling media, avoid equipment damage and service interruption caused by media leakage, which is the bottom-line safety requirement for data center mini electric valves.

2. Precise Flow Regulation (Key for Temperature Control)

Adapt to the dynamic fluctuation of data center computing power loads, realize stable and precise flow regulation, avoid temperature deviation of liquid cooling systems and impact on pipelines, and ensure the stable operation of server equipment.

GRAT IoT Clamp type Butterfly Valve edited

3. Compact Structural Design (Adapt to High-Density Deployment)

Fit the confined space of data center computer rooms and liquid cooling distribution units (CDU), support dense installation of multiple valves, and facilitate subsequent maintenance and replacement to adapt to the high-density layout needs of data centers.

4. Low Power Consumption & High Stability (Help Reduce PUE)

The valve actuator must have low energy consumption and long service life, be able to sustain 7×24-hour continuous operation, and indirectly help reduce the overall PUE of the data center, in line with the green energy-saving development trend of the industry.

II. Core Advantages of GRAT mini Electric Valves for Liquid Cooling Scenarios

Developed specifically for the harsh working conditions of data center liquid cooling, GRAT mini electric control butterfly valves adopt a streamlined design focusing on core performance, achieving perfect adaptation to on-site scenarios and solving the pain points of traditional valves in liquid cooling applications:

Application of Micro Electric Valves in Data Center Liquid Cooling Systems 1 edited

1. Gas-Tight Sealing, Reinforce Liquid Cooling System Safety

With gas-tight zero-leakage performance, it completely eliminates the risk of liquid cooling medium leakage, effectively protecting data center server equipment and pipeline systems. It integrates flow regulation and pipeline shut-off functions in one unit, simplifying pipeline layout, reducing installation and operation and maintenance (O&M) costs, and improving the overall reliability of the liquid cooling system.

2. Equal Percentage Flow Characteristic, Smoother Temperature Control

Designed with equal percentage flow characteristics, it can realize fine micro-adjustment at small openings and fast response at large openings, accurately matching the dynamic load changes of data center liquid cooling systems. The integrated flow channel design minimizes water impact, avoids pipeline vibration and water hammer effect, and ensures long-term stable operation of the liquid cooling system.

3. Compact & Easy Installation, Ideal for High-Density Deployment

Compared with traditional electric valves, GRAT mini electric valves have smaller size and lighter weight, perfectly adapting to the narrow installation space of data center computer rooms and CDU. Adopting clamp connection, it can be quickly assembled and disassembled, greatly improving the efficiency of on-site construction and later maintenance, and meeting the rapid deployment needs of data centers.

DSC02437 edited

4. Low Power Consumption & High Durability, Suitable for 7×24-Hour Operation

Equipped with high-quality brushless motor actuators, it has the advantages of low power consumption, low noise and ultra-long service life, fully compatible with the 7×24-hour non-stop operation mode of data centers, and indirectly helps reduce the overall energy consumption of the liquid cooling system, contributing to the green transformation of data centers.

III. Applicable Scenarios & Core Parameters

Widely applied in cold plate liquid cooling, immersion liquid cooling, room precision air conditioning and other core data center scenarios, compatible with various liquid cooling media. Core parameters fully comply with industry standards:

  • Operating Temperature: -18℃~100℃
  • Connection Type: Clamp Connection
  • Flow Characteristic: Equal percentage; corrosion resistant with stable service life, capable of meeting medium and long-term operation requirements of data centers.
GRAT IoT Clamp type Butterfly Valve 1
GRAT IoT Clamp type Butterfly Valve 2

Against the backdrop of the growing popularity of liquid cooling, the compatibility of micro electric valves has become increasingly critical.

Rooted in the actual operating conditions of data centers, GRAT Control provides reliable, precise and efficient control solutions for liquid cooling systems through practical product design, empowering the industry to achieve green and stable operation.